Error Code E FF
Freezer BLDC fan motor error — no feedback signal from fan motor for more than 65 seconds
Moderate
Address soon - your appliance may not work properly
Also displayed as: E FF
How to Fix
- 1
Reset the unit, then enter Test Mode 1 (press Main PCB test button once). Open the freezer door and check for air flow from the duct. If air is flowing, proceed to step 4.
- 2
If no air flow, manually rotate the fan blade by hand. If the fan feels sticky or does not spin freely, replace the fan motor.
- 3
Check fan motor supply voltage at CON4 Pin 20 ~ Pin 19 in Test Mode 1. Should be 11.4–12.6 V. If voltage is absent, replace Main PCB.
- 4
With supply voltage confirmed, check fan feedback voltage at CON4 Pin 18 ~ Pin 19. If reading is 0 V or 5 V (not a valid feedback signal), replace the fan motor.
- 5
Check PWM signal voltage at CON4 Pin 17 ~ Pin 19. If reading is 0 V or 5 V (not a valid PWM signal), replace Main PCB.
- 6
If all voltages are correct and fan rotates freely, explain to customer (possible temporary obstruction).
This Error Applies To
LG LRFGC2706S Series Refrigerators
Related Error Codes
Humidity sensor error — short-circuit or disconnection of humidity sensor
Freezer icemaker sensor error — short-circuit or disconnection of ice maker sensor
Freezer ice maker kit defect — malfunction of ice maker motor
Freezer sensor error — short-circuit or disconnection of freezer sensor
Defrost sensor error — short-circuit or disconnection of freezer defrost sensor
Defrost heater error — defrost sensor did not reach 40°F (5°C) within 80 minutes after defrost start
Refrigerator sensor error — short-circuit or disconnection of refrigerator sensor
Condenser (machine room) BLDC fan motor error — no feedback signal for more than 65 seconds